71M6513/71M6513H Demo Board User’s Manual
1.7
DEMO BOARD TEST SETUP
Figure 1-1 shows the basic connections of the Demo Board plus Debug Board with the external equipment for
desktop testing, i.e. without live power applied. For desktop testing, both the Demo and Debug board may be
powered with just the 5VDC power supplies.
Power
Demo Board
Power Supply
(100 to 240VAC,
1ADC Output)
Debug
Power
Board
Host PC
Figure 1-1: TERIDIAN D6513T3B2 Demo Board with Debug Board: Basic Connections
The D6513/T3B2 Demo Board block diagram is shown in Figure 1-2. It consists of a stand-alone (round) meter
Demo Board and an optional Debug Board. The Demo Board contains all circuits necessary for operation as a
meter, including display, calibration LED, and internal power supply. The Debug Board, when using a separate
power supply, is optically isolated from the meter and interfaces to a PC through a 9 pin serial port. For serial
communication between the PC and the TERIDIAN 71M6513/71M6513H, the Debug Board needs to be
plugged with its connector J3 into connector J2 of the Demo Board.
The D6513/T3C1 Demo Board System is shown in Figure 1-3. It is almost identical to the D6513T3B2, except
that the neutral current input is added and the optional power and ground connections from the Demo Board to
the Debug Board were removed.
Connections to the external signals to be measured, i.e. scaled AC voltages and current signals derived from
shunt resistors or current transformers, are provided on the rear side of the demo board.
Caution: It is recommended to set up the demo board with no live AC voltage
connected, and to connect live AC voltages only after the user is familiar with
the demo system.
Page: 11 of 112
? 2005-2006 TERIDIAN Semiconductor Corporation
Revision 5.6
相关PDF资料
71M6515H-DB BOARD DEMO 71M6515H ENERGY METER
71M6521FE-DB BOARD DEMO FOR 71M6521FE
71M6531F-DB BOARD DEMO 71M6531F
71M6533-DB BOARD DEMO 71M6533
71M6534H-DB BOARD DEMO 71M6534H
71M6541F-DB DEMO BOARD 71M6541F
71M6543F-DB-CT DEMO BOARD 71M6543F-DB-CT
72-CNV-5 CONVERTER RS-232 TO RS-422 5V
相关代理商/技术参数
71M6513H-IEL 制造商:未知厂家 制造商全称:未知厂家 功能描述:71M6513
71M6513H-IEL/F 功能描述:计量片上系统 - SoC 3-Phase Energy Meter I/C RoHS:否 制造商:Maxim Integrated 核心:80515 MPU 处理器系列:71M6511 类型:Metering SoC 最大时钟频率:70 Hz 程序存储器大小:64 KB 数据 RAM 大小:7 KB 接口类型:UART 可编程输入/输出端数量:12 片上 ADC: 安装风格:SMD/SMT 封装 / 箱体:LQFP-64 封装:Reel
71M6513H-IELR 功能描述:计量片上系统 - SoC 3-Phase Energy Meter I/C RoHS:否 制造商:Maxim Integrated 核心:80515 MPU 处理器系列:71M6511 类型:Metering SoC 最大时钟频率:70 Hz 程序存储器大小:64 KB 数据 RAM 大小:7 KB 接口类型:UART 可编程输入/输出端数量:12 片上 ADC: 安装风格:SMD/SMT 封装 / 箱体:LQFP-64 封装:Reel
71M6513H-IELR/F 功能描述:计量片上系统 - SoC 3-Phase Energy Meter I/C RoHS:否 制造商:Maxim Integrated 核心:80515 MPU 处理器系列:71M6511 类型:Metering SoC 最大时钟频率:70 Hz 程序存储器大小:64 KB 数据 RAM 大小:7 KB 接口类型:UART 可编程输入/输出端数量:12 片上 ADC: 安装风格:SMD/SMT 封装 / 箱体:LQFP-64 封装:Reel
71M6513H-IGT/F 功能描述:计量片上系统 - SoC 3-Phase Energy Meter I/C RoHS:否 制造商:Maxim Integrated 核心:80515 MPU 处理器系列:71M6511 类型:Metering SoC 最大时钟频率:70 Hz 程序存储器大小:64 KB 数据 RAM 大小:7 KB 接口类型:UART 可编程输入/输出端数量:12 片上 ADC: 安装风格:SMD/SMT 封装 / 箱体:LQFP-64 封装:Reel
71M6513H-IGTR/F 功能描述:计量片上系统 - SoC 3-Phase Energy Meter I/C RoHS:否 制造商:Maxim Integrated 核心:80515 MPU 处理器系列:71M6511 类型:Metering SoC 最大时钟频率:70 Hz 程序存储器大小:64 KB 数据 RAM 大小:7 KB 接口类型:UART 可编程输入/输出端数量:12 片上 ADC: 安装风格:SMD/SMT 封装 / 箱体:LQFP-64 封装:Reel
71M6513H-IGTR/F1 功能描述:计量片上系统 - SoC RoHS:否 制造商:Maxim Integrated 核心:80515 MPU 处理器系列:71M6511 类型:Metering SoC 最大时钟频率:70 Hz 程序存储器大小:64 KB 数据 RAM 大小:7 KB 接口类型:UART 可编程输入/输出端数量:12 片上 ADC: 安装风格:SMD/SMT 封装 / 箱体:LQFP-64 封装:Reel
71M6513-IEL 制造商:未知厂家 制造商全称:未知厂家 功能描述:71M6513